Steelmaking ›› 2026, Vol. 42 ›› Issue (6): 84-96.

• Solidification & Continuous Casting • Previous Articles     Next Articles

Study on gas-liquid flow and liquid level fluctuation behavior in wide and heavy slab molds with argon injection

GAO Yong¹ʼ², QIN Xufeng¹ʼ², LI Yang¹ʼ², CHENG Changgui¹ʼ², LIU Yi¹ʼ², YAN Min³, JIN Haibing³   

  1. 1.Key Laboratory of Ferrous Metallurgy and Resources Utilization of Ministry of Education, Wuhan University of Science and Technology, Wuhan 430081, China;2.Hubei Provincial Key Laboratory for New Processes of Ironmaking and Steelmaking, Wuhan University of Science and Technology, Wuhan 430081, China;3.Echeng Steel Co. ,Ltd. ,Baowu Group Zhongnan Iron and Steel Co. , Ltd. , Ezhou 436000, China
  • Online:2026-11-26 Published:2026-11-26

Abstract: Wide and heavy slab molds with section of (200~360) mm × (2 000~2 270) mm from a specific steel plant were taken as the prototype in this study. A 1:0.56 scaled water model was established, and techniques including fluid tracer injection, particle image velocimetry (PIV), high-speed videography and meniscus fluctuation monitoring were employed to investigate the differences in gas-liquid two-phase flow patterns in molds with various cross-sections and the corresponding meniscus fluctuations at different locations. The effects of casting speed, argon flow rates and immersion depth of submerged entry nozzle (SEN) on liquid steel flow behavior, bubble distribution, and meniscus fluctuation in a 360 mm thick mold were systematically examined. The results show that increasing the slab cross-section reduces the momentum of the jet impinging on the narrow face, weakens the upper recirculation flow, lowers the meniscus level near the narrow face, and causes an initial decrease followed by an increase in the meniscus level near the SEN. Among the tested conditions in the 360 mm-thick wide and heavy slab mold, most bubbles float up in the range between the 1/4 width face and the nozzle. Compared with other cross-section molds, the standard deviation of meniscus fluctuation at monitoring point 1 near the narrow face increases slightly, while the standard deviation of meniscus fluctuation at monitoring points 2-4 significantly decreases. Increasing the casting speed from 0.65 m/min to 0.95 m/min enhances both flow velocity and meniscus fluctuation in the mold while reducing the standard deviation of meniscus level. Raising the argon flow rate from 6 L/min to 12 L/min elevates the meniscus level and standard deviation of meniscus fluctuation near the SEN, but slightly lowers the meniscus level near the narrow face. That makes the standard deviation of meniscus level increases, and the uniformity of mold flux distribution deteriorates markedly. Increasing the SEN immersion depth from 110 mm to 155 mm improves the spatial uniformity of bubble distribution and mitigates meniscus fluctuation amplitude; however, the standard deviation of meniscus level first decreases and then increases. To activate the liquid steel flow of near the narrow face and achieve better uniformity in the distribution of the mold flux layer above the meniscus, it is advisable to reduce the argon flow rate from the 8 L/min currently used in industrial production to 6 L/min while maintaining the SEN immersion depth at approximately 125 mm when increasing the casting speed for 360 mm-thick wide and heavy slab mold.

Key words: wide and heavy plate; mold; water model experiment; argon injection; liquid level fluctuation