Development and application of direct connection transmission for water cooling rolls

LI Chaojin, FEI Dongdong, HUANG Hongwei, HUANG Qigang   

  1. (Silicon Steel Department of Wuhan Iron and Steel Co., Ltd., Wuhan 430083, China)
  • Online:2024-08-28 Published:2024-08-23

Abstract: By analyzing the unstable transmission problems of water cooling rolls in a certain silicon steel normalization furnace, such as easy bending deformation, running jumping, and jamming, a direct connection transmission scheme for water cooling rolls is proposed and implemented. After implementation, the water cooling roll transmission is stable, eliminating a series of original problems, and achieving good application results, which is of great application value for improving the production efficiency of steel mills.


Key words: water-cooled roller, rotating joint, direct transmission