Electrical Steel ›› 2019, Vol. 1 ›› Issue (1): 48-54.
Previous Articles Next Articles
SHEN Jie, TANG Ling, ZHOU Xing
Online:
Published:
Abstract: This paper groomed and analyzed the problems of current national standards of measuring methods for alternatingcurrent magnetic properties of electrical steel(including Epstein frame and single sheet test), such as, correcting specific core loss while waveform distorted, assumed effective magnetic path length is not the true one, and lack of calibration method of magnetic test system. And some solutions were also proposed like using digital feeback control technology to avoid correcting specific core loss, assuming effective magnetic path length as 475mm, and comprehensive calibration method for magnetic test system.
Key words: Epstein Frame method, single sheet test, waveform factor, effective magnetic path length, calibration
SHEN Jie, TANG Ling, ZHOU Xing. Application problems of national standards of measuring methods for alternatingcurrent magnetic properties of electrical steel and their solutions[J]. Electrical Steel, 2019, 1(1): 48-54.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: http://www.bwjournal.com/dgg/EN/
http://www.bwjournal.com/dgg/EN/Y2019/V1/I1/48